 Introduction
A new national discharge standard of pollutants for municipal wastewater treatment plant in China has been issued. Odors from wastewater treatment plants must be controlled via means.
We are a fellow subsidiary of Guangdong Petrochemical Engineering Design Institute which has designed gas adsorption system for decades. We have the responsibility and capability to help the plants to control odor. We also have the experience necessary to make your project a success.
Whether your application is sewage lift stations, complete waste treatment, we can service for you . Designing and manufacturing.
Designing and manufacturing
We design and manufactures customized odor control scrubbers and systems to meet customer specific needs. Through the use of a highly trained chemical engineering staff, we can design a unit to meet even the strictest requirements. Major design criteria evaluated include: ventilation, size of unit, packings, scrubbing liquid, recycle rate and material of construction.
Whether your requirements are based on space limitations, system flexibility, maximum efficiency, or a combination of all these, our system is for you: packed bed towers, low profile packaged systems, Multi-stage, Horizontal cross-flow scrubbers, Multi-chemistry
The fabrication of our system is in-house so that the quality of system can be under control.
|
TYPE |
FLOW(m3/h) |
SIZE(L×W×H)mm |
Operating weight(kg) |
Power of blower(KW) |
Power of pumps(KW) |
|
CCZ-1000P |
1000 |
2200×1400×2600 |
2572 |
2.2 |
1.1×3 |
|
CCZ-2000P |
2000 |
2600×1500×2900 |
3479 |
4.0 |
1.1×3 |
|
CCZ-3000P |
3000 |
3000×1600×3100 |
4067 |
5.5 |
1.5×3 |
|
CCZ-4000P |
4000 |
3400×1700×3300 |
4797 |
7.5 |
1.5×3 |
|
CCZ-5000P |
5000 |
3700×1700×3600 |
5506 |
11 |
3.0×3 |
|
CCZ-10000P |
10000 |
4800×2300×4000 |
8751 |
18.5 |
4.0×3 |
|
CCZ-15000P |
15000 |
7000×2200×4600 |
10793 |
22 |
4.0×3 |
|
CCZ-20000P |
20000 |
7800×2200×4600 |
15257 |
45 |
7.5×3 |
|
CCZ-25000P |
25000 |
8600×2200×4700 |
16909 |
45 |
7.5×3 |
|
CCZ-30000P |
30000 |
8600×2200×4700 |
16909 |
45 |
7.5×3 |
General types:
|
TYPE |
FLOW(m3/h) |
SIZE(L×W×H)mm |
Operating weight(kg) |
Power of blower(KW) |
Power of pump1(KW) |
|
CCZ-1000P |
1000 |
1800×1400×2600 |
2492 |
2.2 |
1.1 |
|
CCZ-2000P |
2000 |
2100×1500×2900 |
3374 |
4.0 |
1.1 |
|
CCZ-3000P |
3000 |
2360×1600×3100 |
3929 |
5.5 |
1.5 |
|
CCZ-4000P |
4000 |
2680×1700×3300 |
4634 |
7.5 |
1.5 |
|
CCZ-5000P |
5000 |
2900×1700×3600 |
5324 |
7.5 |
3.0 |
|
CCZ-10000P |
10000 |
3680×2300×4000 |
8453 |
15 |
4.0 |
|
CCZ-15000P |
15000 |
4600×2000×4200 |
10406 |
22 |
4.0 |
|
CCZ-20000P |
20000 |
5400×2200×4600 |
13023 |
30 |
7.5 |
|
CCZ-25000P |
25000 |
6000×2200×4600 |
14751 |
37 |
—— |
|
CCZ-30000P |
30000 |
6600×2200×4700 |
16341 |
37 |
—— |
Economical Types
Advantages of Packed Bed Scrubbers
·Offers the greatest design flexibility ·High mass transfer rates achieved in the national discharge standard requirements ·Economical chemical minimizes operating cost ·Counter-current flow maximizes the driving force for absorption ·Kinds of systems to meet your different requirements ·Low profile requirements ·Excellent equipments guarantee operating stability and minimize the maintenance. ·No solid waste disposal
Typical Applications
·Aeration Basins ·Dewatering Facilities ·Anaerobic Digesters ·Lift Stations ·screening
Some Typical Odors Controlled by our system
H2、NH3、SO2、Amines、Mercaptans
FIELD SERVICES, ENGINEERING, INSTALLATION, START-UP AND OPERATOR TRAINING When the project is completed, We can train your employees to properly operate the equipment. We will help you with any problems and will answer any questions arising during start-up and initial operation procedures. We start-up service will also help your operators to understand the components and the chemistry of your system. Start to finish, we put our experience to work for you from budget and design through start-up and operator training. Our goal is to make your job easier.。
|